SAMBION 710 Series
Horizontal Cylindrical Autoclave
A fully automatic, microprocessor controlled Class B steam sterilizer engineered by Rockwell Industrial Plants Ltd. under the SAMBION brand — built to BIS IS:3829 standards with 8–20 programmable cycles for validated sterilization across CSSD/TSSU, hospital, pharmaceutical and laboratory workflows.

SAMBION 710 — CSSD Solutions
Horizontal Cylindrical Autoclave
A rigid, all-stainless-steel Class B autoclave with fully automatic PLC-driven multi-cycle control and an online printer, purpose-built for hospitals, CSSD/TSSU, pharmaceutical plants and laboratories that need consistent, validated sterilization day after day.
- Fully Automatic — Class B
- CDSCO & BIS Certified
- 8–20 Programmable Cycles
- Stainless Steel Construction
- Colored Touch-Screen HMI
QUICK SPECIFICATION SNAPSHOT
| Specification | Details |
|---|---|
| Capacity | 75L – 5000L (configurable) |
| Automation | Fully Automatic, PLC + HMI, Class B |
| Application | CSSD/TSSU, Hospital, Pharma & Lab |
| Material | SS316L / 304 Chamber & Body |
| Certification | CDSCO, CE, ISO 13485, ISO 9001 |
Product Overview
Fully Automatic Microprocessor Controlled: Class B
The SAMBION 710 series Horizontal Cylindrical Autoclave is factory assembled, tested and fully documented before dispatch. All inner parts are Stainless Steel AISI 304/316/316L/316Ti or above per customer’s choice, with a heavy-duty water ring vacuum pump achieving over 99% air expulsion through purging for consistent, deep-penetration sterilization.
Every unit ships with 8–20 programmable cycles — including pre-start/warmup, leakage test, Bowie & Dick test and HTM/Helix test — selectable at 121°C or 134°C. Behind every machine is Rockwell Industrial Plants Ltd.’s dedicated network of commissioning engineers, delivering on-site installation, training and after-sales support across India and to clients across the Indian subcontinent, Africa, the Middle East and South East Asia.
Key Features
Built for Multi-Cycle Precision & Uptime
Specifications
Technical Specifications
SAMBION 710 series — configurable across chamber sizes to match your CSSD throughput requirements.
| Capacity | 75L – 5000L, configurable to load requirement (Custom Designed available) |
| Chamber Size | Dia 400mm to Dia 1000mm, Length 600mm to 3000mm |
| Chamber Material | SS316L / SS304 |
| Sterilization Temperature | 121°C – 134°C |
| PLC + HMI Control | Fully automatic, colored touch-screen HMI |
| Vacuum Drying | Included, via heavy duty water ring vacuum pump |
| Door Type | Sliding / Hinged, Single or Double door, motorized |
| Steam Generator | Provided / Customer's Boiler / both |
| Thermal Printer | Online printer standard, Circular Data Plotter optional |
| Automation Grade | Automatic / Semi-Automatic / Manual options |
| Power Supply | Single Phase / Three Phase |
| Manufacture License | CDSCO |
| Standards | BIS – IS:3829 Latest Edition with ISI mark |
| Certificates | IAF, NABCB, NSIC, MSME, ISO, CE (MDD), CE (PED), ISO 13485, ISO 9001 |
| Applications | CSSD/TSSU, Hospital, Pharmaceuticals, Laboratory & Bio-Medical Waste |
Full Datasheet
Complete Model Specification Table
Reproduced as per the SAMBION 710 datasheet.
| Capacity (L) | 75-150 L | 90-190 L | 115-290 L | 250-410 L | 470-570 L | 770-1880 L | 1150-2300 L | 75-5000L |
|---|---|---|---|---|---|---|---|---|
| Chamber Size (mm) | Dia 400 x L(600-1250) | Dia 450 x L(600-1250) | Dia 500 x L(600-1500) | Dia 600 x L(900-1500) | Dia 700 x L(1250-1500) | Dia 900 x L(1250-3000) | Dia 1000 x L(1500-3000) | Custom Designed |
| Chamber Material | SS316L/304 | SS316L/304 | SS316L/304 | SS316L/304 | SS316L/304 | SS316L/304 | SS316L/304 | SS316L/304 |
| Sterilization Temperature | 121-134°C | 121-134°C | 121-134°C | 121-134°C | 121-134°C | 121-134°C | 121-134°C | 121-134°C |
| PLC + HMI Control | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Vacuum Drying | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Single / Double Door | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Door Type | Sliding / Hinged | |||||||
| Steam Generator | Provided / Cauterized Boiler / both | |||||||
| Thermal Printer | Optional | |||||||
| Automation Grade | Automatic / Manual | |||||||
| Phase | Single / Three Phase | |||||||
| Applications | PLEASE ASK FOR THE CAPACITY & DUTY AND WE WILL OFFER MOST SUITABLE & ECONOMICAL OPTION CSSD/TSSU, Hospital, Pharmaceuticals, Laboratory & Bio-Medical Waste etc. |
|||||||
| Manufacture License | CDSCO | |||||||
| Standards | BIS – IS:3829 Latest Edition with ISI mark | |||||||
| Certificates | IAF, NABCB, NSIC, MSME, ISO, CE (MDD), CE (PED), ISO 13485, ISO 9001 etc. | |||||||
| ↓ Brochure | Download | Download | Download | Download | Download | Download | Download | Download |
Download Brochure
Please fill in your details to download the brochure.
Applications
CSSD/TSSU, Hospital, Pharma & Laboratory
Working Process
A Validated, Five-Stage Sterilization Cycle
The SAMBION 310 uses a pre-vacuum cycle rather than simple gravity displacement — air is actively drawn out of the chamber before steam is introduced, giving the steam more direct and even contact with the load.
Advantages
Why Hospitals Choose SAMBION 710
Optional Features
Add-Ons for Your Facility
Optional Models
Alternative Configurations
Beyond the standard fully automatic Class B machine, the SAMBION 710 series is also offered in the following configurations.
Frequently Asked Questions
What buyers ask before requesting a quotation
Saturated steam is injected into a sealed, insulated chamber after the water ring vacuum pump expels over 99% of air, raising it to a validated 121°C or 134°C to destroy micro-organisms, followed by vacuum-assisted drying before the door releases.
The SAMBION 710 offers 8–20 programmable cycles, including pre-start/warmup, leakage test, Bowie & Dick test, HTM/Helix test, and multiple customer’s-choice load cycles at 121°C or 134°C.
Every SAMBION sterilizer carries a standard manufacturer’s warranty, backed by our after-sales service network across India and abroad.
Routine preventive maintenance covers door gaskets, HEPA filters and steam trap checks; self-diagnostics and the online printer log flag service needs early to minimise downtime.
Chamber size (75L to 5000L, custom designed available), loading configuration (single or double sliding/hinged door) and automation level (fully automatic, semi-automatic or single-cycle) can all be configured to your CSSD’s throughput needs.
The Horizontal Cylindrical Autoclave is manufactured under a CDSCO licence to BIS IS:3829 (latest edition, ISI mark) and holds IAF, NABCB, NSIC, MSME, ISO, CE (MDD), CE (PED), ISO 13485 and ISO 9001 certification.
Get In Touch
Need a Biomedical Waste Sterilization Solution for Your Facility?
Tell us your expected waste volume, required capacity, facility type and installation location, and our engineering team will help configure a SAMBION 310 system for your site.
No pricing is published online — every configuration is quoted against your site’s specific requirement.